Five fixed devices on eight facades
C4B takes one typical room with one window and turns it to each of eight facade orientations. On every facade it compares five fixed shading devices with the same window left unshaded. The optimiser sizes each device for that facade, and the device with the largest annual energy saving becomes the recommendation. A facade where no device saves at least 1% stays unshaded.
- Overhang: a horizontal plate above the window that blocks the high summer sun.
- Vertical fins: a plate at each side of the window that blocks low sun from the side.
- Eggcrate: overhang and fins combined into a frame that blocks sun from above and from the side.
- Horizontal slats: a screen of tilted blades that blocks sun from above while keeping a view out.
- Vertical slats: a screen of vertical blades that blocks low sun from the side while keeping a view out.
What the analysis shows
- A recommendation overview: a compass of the eight facades with each one's recommended device and its annual saving, and the share of direct sun that device blocks in the cooling season and lets in during the heating season.
- Drawings of each device as an oblique view, a plan and a section, naming the dimensions the results report.
- An annual savings matrix of five devices by eight facades, with the size the optimiser chose for each one and the recommended device highlighted.
- The saving of every device by season and by month, as a share of the unshaded window's annual energy.
How the saving is calculated
Every facade and every candidate device runs through a full year, hour by hour, in an ISO 13790 simple hourly (5R1C) model of the room, on the project's weather file: the nearest weather station's or the site-specific one. A Perez sky model splits the diffuse light into its circumsolar, sky-dome, horizon and ground parts, and the shade each device casts is calculated for the direct sun and for each of those parts.
The saving counts heating, cooling and lighting together, in source energy, and the lights dim with the daylight that reaches the room. A device that keeps out useful winter sun, or darkens the room, therefore counts against itself. Wall and window U-values are the ASHRAE 90.1-2022 prescriptive values for the site's ASHRAE 169 climate zone, and each facade's heating and cooling seasons follow its own balance point, not the calendar.
Your room and your building
The room starts from the project's building type, one of 31 types, each with its own occupancy, equipment and lighting loads, schedules and set points. You can change every input, and the project saves them:
- Room width, depth and height, and the window's size and position on the wall.
- Building type and thermal mass, from very light to very heavy.
- The glazing's solar factor (g-value or SHGC), from 0.10 to 0.87.
- Slat depth and tilt, where the overhang and fins are mounted, and, if you already know them, a fixed overhang depth, fin depth or slat spacing.
- The deepest overhang and fins the optimiser may choose, from 0.10 to 3.00 m (1.50 m unless you change it).
In projects and in the PDF report
Window shading recommendations are part of design direction, in projects on a paid plan. The first time you open it, it runs on the project's defaults; after you change the inputs, Run analysis updates the results. The project's PDF report adds two pages from the weather-station data: the recommendation overview with the inputs used, and the annual savings matrix.
See your site's climate before design begins
Pin any location and get climate, comfort and preliminary energy insight your whole team can read. Start with a 7-day free trial, or book a 30-minute demo.
Free plan; paid plans from €59/month (cancellation takes effect after 12 billing cycles) or €599/year, with a 7-day free trial. No card required. If you add a card during the trial, the plan is charged when the trial ends; otherwise your account moves to the Free plan. See all plans.
Frequently asked questions
Does this replace a detailed shading or energy simulation?
No. It is a screening analysis for early design. The savings describe one typical room, so they compare devices and orientations with each other rather than predict your building's energy use. Confirm the shortlisted device with a whole-building simulation later in the project.
Why are the devices ranked on energy and not on blocked sun?
A device that blocks summer sun also blocks some winter sun and daylight. Ranking on the annual heating, cooling and lighting energy weighs all three, so the recommendation is the device that helps the room most over the whole year.
What does it mean when a facade reads Unshaded?
None of the five devices saves at least 1% of the unshaded window's annual energy on that facade, so a fixed shading device is not worth building there for this room and climate.
Does it compare movable blinds or solar-control glass?
No. It compares five fixed external devices. The glazing's solar factor is an input instead: below a g-value of about 0.40 the glass already shades the room, and every device saves less.
Does it include future climate?
Not yet. The recommendations run on the project's present-day weather files: the nearest weather station's and the site-specific one.
Learn the concepts
How to read a sun path diagram
Altitude, azimuth, date and hour lines, polar and cylindrical charts, and how shading masks test overhangs and fins.
Passive design strategies by climate
How bioclimatic charts link ventilation, thermal mass, evaporative cooling, internal gains and passive solar heating to the climates where they work.
Climate-responsive design
The principles of climate-responsive design, and the strategies that suit hot-dry, hot-humid, temperate and cold climates, grounded in building science sources.
Related features
Sun path diagram
Sun path diagrams in 2D, 3D and globe views, together with monthly daytime cloud cover.
Preliminary energy analysis
An hourly preliminary energy balance and orientation and aspect-ratio optimization for early design.
Psychrometric chart and passive design
An hourly psychrometric chart and the share of hours covered by each passive design strategy.