Sustainability certification guides

Certification contribution by module

Every criterion in LEED, BREEAM, DGNB and VERDE that a live C4B module contributes to, with the value the scheme attaches to it.

Last reviewed23 October 2026

What the symbols mean

  • (+)
    Can contribute towards points or creditsThe module delivers some or all of the analysis or evidence the criterion is scored on.
  • →
    Provides design directionThe module shapes the design decision; the credit is earned once the team develops the design in detail and documents it.
  • •
    Provides the data basisThe module supplies some or all of the underlying data; the team interprets it and produces the evidence required to claim the point.
  • –
    No contributionNothing in this scheme that the module speaks to.

Contribution by module, criterion by criterion

ModuleLEED v4.1 BD+CBREEAM International NC v7.1DGNB New Construction 2023VERDE Edificios 2030
Climate
Location Information and Data Summary
(+)
  • Site Assessment (1 pt)
  • Integrative Process (1 pt)
•
  • Hea 10 Natural hazards (1 cr)
  • Wst 05 Adapting to climate change (1+1 cr)
(+)
  • SITE1.1 Local environment (85 pts · 2.13 %)
  • ECO2.6 Climate resilience (45 pts · 2.25 %)
(+)
  • EE 03 Riesgos climáticos (4.02 %)
Climate Zone
•
  • Site Assessment (1 pt)
–
•
  • SITE1.1 Data basis (15 of 85 pts)
•
  • EE 03.01 Riesgos físicos (1.61 %)
Typical Hourly Temperature, Humidity and Adaptive Comfort
→
  • Thermal Comfort (1 pt)
→
  • Hea 05 Thermal comfort (3 cr)
→
  • SOC1.1 Thermal comfort (35 pts · 1.47 %)
  • ECO2.6 Climate resilience (45 pts · 2.25 %)
→
  • ES 04.02 Horas fuera de consigna (1.45 %)
Precipitation Overview
•
  • Rainwater Management (3 pts)
  • Site Assessment (1 pt)
•
  • Pol 03 Flood and surface water (5 cr)
–
–
Precipitation Event Intensity
(+)
  • Rainwater Management (3 pts)coming soon
•
  • Pol 03 Flood and surface water (5 cr)
–
–
Sun Path Diagrams
(+)
  • Site Assessment (1 pt)
–
–
→
  • CC 01 Diseño bioclimático (2.97 %)
Monthly Daytime Cloud Coverage OverviewOnly in connection with a daylight simulation
–
–
–
–
Annual and Daily Wind Rose Diagrams
(+)
  • Site Assessment (1 pt)
–
→
  • SOC1.6 Quality of outdoor spaces (20 pts · 0.84 %)
–
Outdoor Comfort (UTCI)
(+)
  • Site Assessment (1 pt)
–
→
  • SOC1.6 Quality of outdoor spaces (20 pts · 0.84 %)
–
Energy
Psychrometric Chart
–
–
–
–
Country Grid Carbon Intensity Assessment
•
  • Grid Harmonization (2 pts)
•
  • Ene 07 Flexible demand response (1 of 2 cr)
•
  • ENV1.1 Climate action and energy (10 pts · 1.04 %)
–
Solar Radiation
–
→
  • Ene 04 Low carbon design (2 of 5 cr)
→
  • TEC1.3 Quality of the building envelope (10 of 25 pts)
→
  • CC 01 Diseño bioclimático (2.97 %)
PV Energy: Aggregate Yearly Potential
→
  • Renewable Energy (5 pts)
→
  • Ene 04 Low carbon design (2 of 5 cr)
(+)
  • TEC1.3 PV application potential (10 pts · 0.22 %)
  • TEC1.4 Renewable generation (20 of 60 pts)
→
  • CE 03.01 Energías limpias en la parcela (4.65 %)
Wind Energy: Aggregate Yearly Potentialcoming soon
→
  • Renewable Energy (5 pts)
→
  • Ene 04 Low carbon design (2 of 5 cr)
→
  • TEC1.4 Renewable generation (20 of 60 pts)
→
  • CE 03.01 Energías limpias en la parcela (4.65 %)
Geothermal Potential
→
  • Renewable Energy (5 pts)
→
  • Ene 04 Low carbon design (2 of 5 cr)
→
  • TEC1.4 Use of renewable sources (10 of 60 pts)
→
  • CE 03.01 Energías limpias en la parcela (4.65 %)
Preliminary Energy Balance
(+)
  • Optimize Energy Performance (18 pts)
  • Integrative Process (1 pt)
  • Minimum Energy Performance (prerequisite)
(+)
  • Ene 01 Regulated energy uses (9+3 cr)
  • Ene 02 Energy strategy (1 of 12 cr)
(+)
  • ENV1.1 Climate action and energy (10 pts · 1.04 %)
  • ECO1.1 Life cycle cost variants (15 pts · 1.5 %)
→
  • CE 01 Consumo de energía primaria (6.24 %)
  • ES 04.01 Demanda calef./refrig. (1.45 %)
Country Average Embodied / Operational Energy Ratioscoming soon
•
  • Building Life-Cycle Impact Reduction (5 pts)
•
  • Mat 01 Building life cycle assessment (7+3 cr)
•
  • ENV1.1 Life cycle CO₂ balance (10 pts · 1.04 %)
•
  • CM 03.01–03 Análisis de ciclo de vida (5.28 %)
Design direction
Passive Design Strategies for Indoor Environments
(+)
  • Optimize Energy Performance (18 pts)
  • Integrative Process (1 pt)
  • Thermal Comfort (1 pt)
→
  • Ene 01 Regulated energy uses (9+3 cr)
  • Hea 05 Thermal comfort (3 cr)
  • Wst 05 Adapting to climate change (1+1 cr)
  • Ene 04 Low carbon design (1 of 5 cr)
(+)
  • ECO2.6 Climate resilience (45 pts · 2.25 %)
  • SOC1.1 Thermal comfort (35 pts · 1.47 %)
  • TEC1.4 Passive building concept (40 of 60 pts)
→
  • CE 01 Consumo de energía primaria (6.24 %)
  • CC 01.01 Estrategias bioclimáticas (0.99 %)
  • ES 04.02 Horas fuera de consigna (1.45 %)
  • EE 03.02 Soluciones (0.80 %)
Comfort Strategies for Outdoor Environments
–
–
→
  • SOC1.6 Quality of outdoor spaces (20 pts · 0.84 %)
  • ECO2.6 Climate resilience (45 pts · 2.25 %)
→
  • EE 03.04 Condiciones exteriores (0.40 %)
Optimal PV Panel Orientation
→
  • Renewable Energy (5 pts)
→
  • Ene 04 Low carbon design (2 of 5 cr)
(+)
  • TEC1.3 PV application potential (10 pts · 0.22 %)
→
  • CE 03.01 Energías limpias en la parcela (4.65 %)
Energy Use: Orientation and Aspect Ratio Optimization
(+)
  • Optimize Energy Performance (18 pts)
  • Integrative Process (1 pt)
(+)
  • Ene 04 Building form optimisation (1 cr)
→
  • ENV1.1 Climate action and energy (10 pts · 1.04 %)
  • ECO1.1 Life cycle cost variants (15 pts · 1.5 %)
→
  • CE 01 Consumo de energía primaria (6.24 %)
Directional Outdoor Comfort Strategies
–
–
→
  • SOC1.6 Quality of outdoor spaces (20 pts · 0.84 %)
–
Window Shading Recommendations
–
–
→
  • SOC1.6 Quality of outdoor spaces (20 pts · 0.84 %)
→
  • CC 01.02 Control solar de la envolvente (1.98 %)
Daylight Analysiscoming soonsDA and ASE to IES LM-83; daylight provision, sunlight and glare to EN 17037
→
  • Daylight (up to 3 pts)
→
  • Hea 01 Visual comfort: daylighting, glare control, direct sunlight (up to 4 cr)
→
  • SOC1.4 Visual comfort, indicators 1 and 4 (40 of 100 pts · 1.68 %)
→
  • ES 02.01 Iluminación natural (0.87 %)
  • ES 02.02 Protección contra el deslumbramiento (0.87 %)
  • EI 01.02 Exposición a la luz del sol (1.53 %)
PV and Wind Energy Potential: Yearly Distributioncoming soon
→
  • Renewable Energy (5 pts)
  • Grid Harmonization (2 pts)
→
  • Ene 04 Low carbon design (2 of 5 cr)
  • Ene 07 Flexible demand response (1 of 2 cr)
→
  • TEC1.4 Renewable generation (10 of 60 pts)
→
  • CE 03.01 Energías limpias en la parcela (4.65 %)
Suggested Focus for Reducing Overall Carbon Emissionscoming soon
→
  • Optimize Energy Performance (18 pts)
  • Building Life-Cycle Impact Reduction (5 pts)
→
  • Mat 01 Building life cycle assessment (7+3 cr)
→
  • ENV1.1 Climate action and energy (10 pts · 1.04 %)
  • ECO1.1 CO₂ price variant (7.5 pts · 0.75 %)
→
  • CM 03 Análisis de ciclo de vida (5.28 %)
Technical and reporting
Technical Comfort Strategies
→
  • Thermal Comfort (1 pt)
→
  • Hea 05 Thermal comfort (3 cr)
→
  • SOC1.1 Thermal comfort (35 pts · 1.47 %)
→
  • ES 04.02 Horas fuera de consigna (1.45 %)
Wind Protection Module (beta)
–
–
→
  • SOC1.6 Outdoor common areas (15 of 20 pts · 0.84 %)
→
  • EE 03.04 Condiciones exteriores (0.40 %)
Project Summary: Climate, Energy + Comfort, PrecipitationAssessor-facing evidence
(+)
  • Site Assessment, Integrative Process (2 pts)
  • Rainwater Management (3 pts) · percentile rainfall depths coming soon
•
  • Hea 10, Wst 05, Pol 03 (7+1 cr)
(+)
  • SITE1.1, ECO2.6 (130 pts · 4.38 %)
(+)
  • EE 03 Riesgos climáticos (4.02 %)

How to read this table

  • Values in brackets are what the scheme itself attaches to the criterion: LEED points out of 110, BREEAM credits (standard + exemplary), DGNB criterion points with the weighted share of the certificate, and the VERDE share of the final score.
  • Partial scope means the module supports part of what the criterion asks for; the rest sits outside the platform.
  • Values recur down a column because a criterion appears against every module that feeds it. They are ceilings on what C4B contributes towards, not points the platform awards: every credit is earned by the design team and reviewed by the assessor.
  • Strongest contribution: where a module contributes in more than one way to the same scheme, the symbol shows the strongest. A cell marked (+) also informs the design; one marked → also supplies data.